Scope of application:
For priming clean metal surfaces or surfaces that have corrosion traces with a corrosion layer thickness of not more than 10 microns.
PF, GF, AU, UrF, “Aurora-Express”.
Properties:
Technical details:
Composition | Alkyd-urethane semi-finished varnish, pigments, fillers, solvents, sativa and other targeted additives |
Dry residue | 58-76% |
Relative viscosity | Not less than 50 s |
Dilution rate | Not more than 25% |
Solvent | Solvent, xylene, white spirit or mixture |
Packaging | 0.9 kg; 2.8 kg; 50 kg |
Warranty period of storage | 6 months from date of manufacture |
Primer Application Guide:
Application methods | Working viscosity (VZ-246) | |
roller brush | (35-40) with | |
pneumatic spraying | (18-22) with | |
airless spray | (25-30) s | |
immersion | (16-25) with |
Working conditions | Air temperature when painting not lower than +5 wasps |
Drying time | At a temperature (18-22) wasps and a relative humidity of 65% – up to 4 hours.
At a temperature (78-82) Oc – up to 30 minutes. Low temperature during the drying time. |
Primer consumption | On a single-layer coating – (60-120 g / m2). |
Single layer coating thickness | (15 – 20) microns – when applied by spraying methods
(25 – 30) microns – when applied with a roller or brush For applying a high-quality coating, 1-2 coats of primer are recommended. Drying at a temperature of (18-22) Oc – 1 hour |
Cleaning tools | Solvent |
Surface preparation:
Remove dust, dirt, paint, peeling, fat and other contaminants.
The surface must be dry and clean.
Preparation of the primer:
Mix thoroughly and dilute to working viscosity.